Cole-Parmer Ltd. (Jenway)
Spectrophotometer Models 7310 / 7315
Article number: 9775442
Product information "Spectrophotometer Models 7310 / 7315"
Models 7310 and 7315 use icon driven software and have an improved navigation system for easy and intuitive usability. These instrument have measurement modes for absorbance, % transmittance, concentration, scanning, kinetics and quantitation. The 7310 and 7315 are easy to use and are ideal for routine testing in clinical, veterinary, pharmaceutical and QC laboratories.
Supplied with: Mains lead, pack 100 disposable cuvettes, 10 x 10mm cell holder, 2GB USB memory stick, interface cable, PC Application Software on CD-ROM and operating instructions.
Accessories available include an automatic 8 cell changer, Peltier, sipper pump, combined sipper Peltier pump, adjustable path length cuvette holders and micro-cuvette holders. Cuvettes and lamps are available on request.
- Small footprint
- Autologging capabilities
- Press to read xenon lamp (7315)
- Result and method storage to USB memory stick
- PC software included
- 3 year warranty
Supplied with: Mains lead, pack 100 disposable cuvettes, 10 x 10mm cell holder, 2GB USB memory stick, interface cable, PC Application Software on CD-ROM and operating instructions.
Accessories available include an automatic 8 cell changer, Peltier, sipper pump, combined sipper Peltier pump, adjustable path length cuvette holders and micro-cuvette holders. Cuvettes and lamps are available on request.
Specifications Optical system: | Single beam |
Wavelength Range: Resolution: Accuracy: Bandwidth: | 320 to 1000nm (7310) 198 to 1000nm (7315) 1nm ± 2nm 5nm |
Transmittance Range: Resolution: Stray light: Accuracy: |
0 to 199.9%
0.1%
|
Absorbance: | -0.3 to 2.500 |
Concentration: Range: Resolution: Calibration: | -300 to 9999 Selectable 1, 0.1, 0.01 or 0.001 Blank with a single standard or factor |
Quantitation: Range: Resolution: Calibration: Curve fit algorithms: | -300 to 9999 Selectable 1, 0.1, 0.01 or 0.001 Blank with up to 6 standards Linear regression, interpolation, quadratic, quadratic through zero or linear regression through zero |
Kinetics display: | Graphical rate of change, initial and final absorbance/%T and calculated concentration value against standard and factor |
Spectrum: Scan Data Internal: Analysis: | 320 to 1000nm (7310) 198 to 1000nm (7315) 1, 2 or 5nm selectable Absorbance and wavelength of peaks and troughs |
Outputs: | USB, analogue and serial RS232, optional integrated printer |
Supply requirements: | 230V/50Hz |
Dual Use: | 0 |
---|---|
Manufacturer Article Number: | 731 001 |
Type: | 7310 |